Required resources

<< 点击显示目录 >>

主页  轴控开发使用手册 > ACP10/ARNC0帮助信息 > ACP10_MC运动库 > 分类的功能块 > 色标控制 (MC_RegMa-Library) > MC_BR_RegMarkCapture002  >

Required resources

This function block requires cyclic read data from the drive in order to operate.

The cyclic read data represents a load on the system and bus. A limited number of data bytes are available per transferred record depending on the bus type being used. A large amount of read data can reduce the rate at which data is updated.

Cyclic data:

BIT_VALUE_UI2+ Resource_Number

UINT

(2 bytes)

ACP10PAR_LATCH_ERROR_COUNT+ Resource_Number (1 byte)

 

 

 

ACP10PAR_LATCH_STATUS_COUNT+ Resource_Number (1 byte)

 

 

 

ACP10PAR_LATCH_VALUE+ Resource_Number

DINT

(4 byte)

In addition, the following SPT resources from the area reserved for PLCopen are required:

1xDELAY, 1xLATCH, 1xBIT