<< 点击显示目录 >> 主页 轴控开发使用手册 > ACP10/ARNC0帮助信息 > ACP10_MC运动库 > 分类的功能块 > 色标控制 (MC_RegMa-Library) > MC_BR_RegMarkCapture002 > Additional information |
When the drive's trigger input is used, the input delay is approximately 50 µs (see also Motion control hardware). Speed-dependent error is compensated with corresponding hardware support.
If a different input is used, then the respective documented input delay and evaluation of the input status must be taken into account in the 400 µs cycle of the drive.