<< 点击显示目录 >> 主页 轴控开发使用手册 > ACP10/ARNC0帮助信息 > ACP10_MC运动库 > 分类的功能块 > 色标控制 (MC_RegMa-Library) > MC_BR_RegMarkCapture002 > Timingdiagramm InitData > Procedure with varying product lengths with MC_BR_CrossCutterControl |
•Change ".ProductLength" before the last registration mark or at the registration mark before the last change.
•Perform an update procedure with "InitData" (for MC_BR_RegMarkCapture002).
•The registration mark after the next is detected with a changed length.
•The current product length is temporarily stored in a separate variable or FIFO buffer.
•After the distance (".DistanceToSensor"-".ProductLength") has been traversed, the new product length can be copied to "ProductLength" of MC_BR_CrossCutterControl.
•Trigger "InitData" for MC_BR_CrossCutterControl if "InCompensation" is reported.
•The next product interval is then also cut with the changed product length.
•Repeat this procedure the next time the product length changes.
The "AdvancedParameters.CorrectCurrentCycle" option has no effect on this procedure.