"Enable", "InitData" inputs

<< 点击显示目录 >>

主页  轴控开发使用手册 > ACP10/ARNC0帮助信息 > ACP10_MC运动库 > 分类的功能块 > 色标控制 (MC_RegMa-Library) > MC_BR_RegMarkCapture002  >

"Enable", "InitData" inputs

"Enable" is used to enable the function block. The "Active" output is then set after the necessary parameters have been initialized on the drive.

The "Busy" output is set immediately after "Enable" and remains active while execution is ongoing.

All input parameters are applied when the "Enable" input is set. All parameters except for those listed below are changed during operation on a rising edge of the "InitData" input.

"CutPosition": This value is applied any time a change occurs.

"Master" and "Axis" axis references: Requires the function block to be restarted via "Enable".

"AdvancedParameters.Mode": Requires the function block to be restarted via "Enable".

"Configuration.RegMarkOffset":This value is applied any time a change occurs.

Initializing MC_BR_CrossCutterControl (or another multi-axis coupling function block) is sufficient for executing MC_BR_RegMarkCapture002.