<< 点击显示目录 >> 主页 轴控开发使用手册 > ACP10/ARNC0帮助信息 > ACP10_MC运动库 > 分类的功能块 > 色标控制 (MC_RegMa-Library) > MC_BR_RegMarkCapture001 > Trigger parameters ("TriggerInput") > Parameter for detecting the interval start |
At the beginning of a product interval, the function block determines the current position of the axis on which registration mark detection is running (except for "Mode" = +mcLENGTH_ONLY). The start can be detected based on a master position or an event.
For a fixed master reference, "TriggerInput.MasterInterval" can be used to define the length of a product cycle on the master side; "TriggerInput.IntervalLevel" can be used to define the starting position of the interval based on the master position.
If an event should be used to form the interval start, additional option +mcINTERVAL_EVENT for "Mode" must be used. The effects of the values of input structure "TriggerInput" are described in section Operating mode ("Mode").