Additional options for the operating mode

<< 点击显示目录 >>

主页  轴控开发使用手册 > ACP10/ARNC0帮助信息 > ACP10_MC运动库 > 分类的功能块 > 色标控制 (MC_RegMa-Library) > MC_BR_RegMarkCapture001  > Operating mode ("Mode")  >

Additional options for the operating mode

Value

Description

+mcINTERVAL_EVENT (+16)

Accounts for the settings with regard to the interval event ("TriggerInput.IntervalSourceParID)

Without this option, the value of "TriggerInput.MasterInterval" is used by default to generate the interval start.

+mcLENGTH_ONLY (+32)

Provides only length specifications on the function block outputs. No value is output on outputs "PositionError" and "ActIntervalLength".

All specifications for the master interval or interval event are not necessary. A combination of +mcLENGTH_ONLY and +mcINTERVAL_EVENT does not make sense.

+mcMANUAL_SEARCH (+64)

Disables automatic searching for a registration mark according to the configuration. Searching for registration marks must always be enabled manually ("SearchTrigger" = 1).

Note:

A manual search for the registration mark is only possible if "ProductParameters.SearchMode" = mcON and ProductParameters.LengthChange ≠ 0.

+mcCONTINUE_CONTROLLER_OFF (+128)

Function block continues performing its function when the axis controller ("Axis") is turned off. Without this additional option, the function block reports an error and must be re-enabled using the "Enable" input.

Note:

The axis positions must be restored before the coupled movement is resumed. Otherwise, the interval setting no longer matches the product parameters.